Nonconducted And Conducted PAC's

Frank Yanowitz Copyright 1996

The pause in this example is the result of a nonconducted PAC, as indicated by the first arrow. The second arrow points to a conducted PAC. The most common cause of an unexpected pause in rhythm is a nonconducted PAC.